1
9532P-62 (03-11) A
1
Appendix A
C
98-50LN – 50-foot System Cable
(P/N 40893G-12)
I
NSTALLATION SHEET
The C98-50LN System Cable interfaces a H9800-series headset with the David Clark Series
9800 Marine Intercom System, and allows for the installer to trim the length of the cable as
needed. The installer must also attach the mating connector (P/N 13265P-55). This sheet
provides instructions for the proper installation of this connector.
The 13265P-55 Connector Kit
c
ontains the following items:
You will need the following parts/tools to
c
omplete the installation:
1
. O-Ring
2. Twist-Lock Ring
3. Connector Body
4. Rubber Grommet
5. Plastic Compression Ring
6. Backshell
• Wire Cutters
• Wire Strippers
• Soldering Iron & Solder
• 1/8-inch (ID) Shrink Tubing
• Silicone Spray
T
able A1: Connector Kit Parts & Tools Required
Procedure
1. Cut C98-50LN Cable to length as needed.
2. Slide backshell (6) onto cable (Figures A2 & A3)
3. Slide rubber grommet (4) onto cable (Figures A2 & A3).
Use silicone spray as necessary.
4. Slide twist-lock ring (2) onto cable (Figures A2 & A3).
5. Strip cord outer jacket 1/2-inch.
6. Strip individual conductors 1/8-inch.
7. Twist shield together and use shrink tubing to insulate.
8. Solder wires and shield to connector body (3) as indicated. See Figure A1 & Table A2.
9. Position compression ring (5) as shown in Figures A2 & A3. Note that the ring comes in
two halves. Do NOT break them apart. Instead, fold them to make a ring, and position
over the thin part of the rubber grommet.
10. Slide grommet with ring into backshell and twist lock backshell onto main connector
body (Figure A3).
11. Slide O-ring (1) over contact end of the connector.